From AWS D1.1:2004 Sections 5.3.1.4 and 5.3.1.5, “Welding consumables that have been removed from the original package shall be protected and stored so that the welding properties are not affected. Electrodes shall be dry and in suitable condition for use.” In addition, AWS D1.1:2004 Section 5.3.2 contain provisions for storage and baking for low-hydrogen electrodes, which are more susceptible to moisture absorption.